/[CCFs]/ccfdev/packages/xmm-siam/ChangeLog
ViewVC logotype

Contents of /ccfdev/packages/xmm-siam/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log


Revision 1.7 - (show annotations)
Mon May 21 16:10:01 2001 UTC (23 years, 6 months ago) by cerd
Branch: MAIN
CVS Tags: version_9, version_0_9, HEAD
Changes since 1.6: +13 -0 lines
Version 9, all X-ray instruments common

1 ChangeLog for xmm-siam
2 ----------------------
3
4 Version 9 - 2001-05-21 (CE)
5 ---------
6 + issue 9
7 + this involves the following offsets w.r.t. issue 5:
8
9 delta_R_y delta_R_z
10 RGS1 +22.3 arcsec +15 arcsec
11
12 + the angles for all instruments are identical, except OM, which
13 remains unchanged
14
15 Version 8 - 2000-12-18 (CE)
16 ---------
17 + issue 8
18 + unfortunately the angles used for creation of in issue 7 where
19 wrong, expect Ry for RGS. Here is the new offsets w.r.t. issue 5:
20
21 delta_R_y delta_R_z
22 RGS1 +53.6 arcsec +15 arcsec
23 EPN -20 arcsec +80 arcsec
24
25
26 Version 7 - 2000-09-28 (CE)
27 ---------
28 + issue 7
29 + change of the SIAM angles of all EPIC camera to be at the full
30 value of what is desired by EPN. Angles w.r.t. SIAM_0005 are
31
32 delta_R_y delta_R_z
33 RGS1 +53.6 arcsec -15 arcsec
34 EPN +20 arcsec -80 arcsec
35
36 + SIAM angles of RGS are as in Version 6 (minor numerical change
37 due to change of program; this was really made for consistency only).
38
39 Version 6 - 2000-09-19 (CE)
40 ---------
41 + issue 6
42 + split into RGS and EPIC (pn) SIAM angles; the EPIC angles are an
43 intermediate value of what is desired by EPN.
44 + we are shifting the following rotations w.r.t. the previous SIAM
45 angles.
46
47 delta_R_y delta_R_z
48 RGS1 +53.6 arcsec -15 arcsec
49 EPN +20 arcsec -15 arcsec
50
51 + from this version onwards we have to provide the SIAM_????.CCF
52 which has the format of the BORESIGHT CCF to VILSPA
53 + the values derived for EPN are copied to EMOS1 & EMOS2, those
54 found for RGS1 are also copied to RGS2; OM angles are untouched
55
56 Version 5 - 2000-06-15 (RM)
57 ---------
58 + issue 5
59 + update only affects OM: centers boresight in OM FOV.
60 Needed for correct positioning of fast mode windows.
61 boresight averaged over 12 observations
62 (based on Alice Breeveld's email Date: Tue, 13 Jun 2000 14:41:20 +0100)
63 Distortion correction applied to STR position.
64 However there is still an one pixel ambiguity due to mixing of SAS
65 and IDL pixel addressing convention.
66
67 Version 4 - 2000-02-29 (RM)
68 ---------
69 + issue 4
70 + best estimates for EPIC & OM, no changes for RGS
71 + first use: rev 44 (2000-03-05 07:00:00)
72
73 Version 2 - 2000-02-02 (RM)
74 ---------
75 + issue 2
76 + at the request by PX all instruments are put at the same
77 pointing to enable the use of the small window mode of MOS
78 + first use: rev 31 (2000-02-08)
79
80 Version 1 - 2000-01-26 (RM)
81 ---------
82 + only OM updated
83 + never used, as only the OM was updated.
84 Version 0.1 - 1900-09-19 (CE)
85 -----------
86 + initial version
87