1 dlumb 1.1 ChangeLog for epn-quantumef
2     ===========================
3 rsaxton 1.11 Version 1.2 - 2002-01-24 (RDS)
4     -----------
5     Added pattern fraction extensions (SCR-72)
6    
7 dlumb 1.10 Version 1.1 - 2001-08-02 (DL)
8     -----------
9     Last energy point erroneously set at 30. and not 30000.
10 dlumb 1.9 Version 1.0 - 2001-07-20 (DL)
11     -----------
12     Improved the anchoring point to 0eV and 30keV.
13     The new knowledge of the pattern ratios and better estimates of overall
14     QE are ingested to provide a better match to the arfgen generation
15     to the supplied instrument matrices. Note there are still problems at
16     energies <500eV that will need o be fixed by workin in PHA space and
17     not PI domain
18    
19 dlumb 1.8 Version 0.8 - 2000-10-31 (DL)
20     -----------
21     The interpolation regime was not workin properly on version 0.7. Traced
22     to a lack of anchoring points at low and high energies.
23    
24 dlumb 1.7 Version 0.7 - 2000-09-18 (DL)
25     -----------
26     The ratio of singles ; doubles is updated according to an energy
27     dependent expression provided by Frank Haberl. However this is only
28     valid for on-axis, as there is an energy dependence of thresholds due
29     to CTI effects which will modify the off-axis sources.
30 dlumb 1.6 Version 0.6 - 2000-09-18 (DL)
31     -----------
32     The REGION expression was being truncated, and upset the CAL.
33     Now the string expression is read into a 128 character long field
34 dlumb 1.5 Version 0.5 - 2000-09-08 (DL)
35     -----------
36     +Having examined in-orbit data it is clear that the ratio of singles to
37     doubles events is incorrect. As the spectroscopic fitting of data
38     relies only on singles the whole ARF generation will be wrong. The QE
39     files therefore have been updated. Some furtehr modifications
40     will no dount be needed subject to inputs from MPE analysis.
41    
42 dlumb 1.4 Version 0.4 - 2000-06-27 (DL)
43     -----------
44     + changed the region expression to rectangle, and removed the dead
45     first 10 rows from the Quantum-eff file, and placed into the FOV
46     extension of EPN LINCOORD
47    
48 dlumb 1.3 Version 0.3 - 2000-05-30 (DL)
49     -----------
50     + changed the CCD DEFINITIONS FROM 0-2 (PER QUAD) TO 1-12
51    
52 dlumb 1.2 Version 0.2 - 2000-05-08 (DL)
53     -----------
54     + fixed the ebins from keV to eV
55 dlumb 1.1 Version 0.1 - 2000-04-03 (DL)
56     -----------
57     + created by DL