/[CCFs]/ccfdev/packages/epn-quantumef/ChangeLog
ViewVC logotype

Annotation of /ccfdev/packages/epn-quantumef/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log


Revision 1.10 - (hide annotations)
Fri Aug 3 13:45:45 2001 UTC (23 years, 3 months ago) by dlumb
Branch: MAIN
CVS Tags: version_0_9, version_1_1
Changes since 1.9: +3 -0 lines
Committed through make

1 dlumb 1.1 ChangeLog for epn-quantumef
2     ===========================
3 dlumb 1.10 Version 1.1 - 2001-08-02 (DL)
4     -----------
5     Last energy point erroneously set at 30. and not 30000.
6 dlumb 1.9 Version 1.0 - 2001-07-20 (DL)
7     -----------
8     Improved the anchoring point to 0eV and 30keV.
9     The new knowledge of the pattern ratios and better estimates of overall
10     QE are ingested to provide a better match to the arfgen generation
11     to the supplied instrument matrices. Note there are still problems at
12     energies <500eV that will need o be fixed by workin in PHA space and
13     not PI domain
14    
15 dlumb 1.8 Version 0.8 - 2000-10-31 (DL)
16     -----------
17     The interpolation regime was not workin properly on version 0.7. Traced
18     to a lack of anchoring points at low and high energies.
19    
20 dlumb 1.7 Version 0.7 - 2000-09-18 (DL)
21     -----------
22     The ratio of singles ; doubles is updated according to an energy
23     dependent expression provided by Frank Haberl. However this is only
24     valid for on-axis, as there is an energy dependence of thresholds due
25     to CTI effects which will modify the off-axis sources.
26 dlumb 1.6 Version 0.6 - 2000-09-18 (DL)
27     -----------
28     The REGION expression was being truncated, and upset the CAL.
29     Now the string expression is read into a 128 character long field
30 dlumb 1.5 Version 0.5 - 2000-09-08 (DL)
31     -----------
32     +Having examined in-orbit data it is clear that the ratio of singles to
33     doubles events is incorrect. As the spectroscopic fitting of data
34     relies only on singles the whole ARF generation will be wrong. The QE
35     files therefore have been updated. Some furtehr modifications
36     will no dount be needed subject to inputs from MPE analysis.
37    
38 dlumb 1.4 Version 0.4 - 2000-06-27 (DL)
39     -----------
40     + changed the region expression to rectangle, and removed the dead
41     first 10 rows from the Quantum-eff file, and placed into the FOV
42     extension of EPN LINCOORD
43    
44 dlumb 1.3 Version 0.3 - 2000-05-30 (DL)
45     -----------
46     + changed the CCD DEFINITIONS FROM 0-2 (PER QUAD) TO 1-12
47    
48 dlumb 1.2 Version 0.2 - 2000-05-08 (DL)
49     -----------
50     + fixed the ebins from keV to eV
51 dlumb 1.1 Version 0.1 - 2000-04-03 (DL)
52     -----------
53     + created by DL

  ViewVC Help