1 dlumb 1.6 ChangeLog for emos-quantumeff
2     ============================
3     VERSION 0.6 - 2000-09-6 (DL)
4     -----------
5     Further analysis of fligh tdata at Licester allowed better
6     reconciliation with the analytical QE models. In addition we
7     introduce far more energy data to allow for better interpolation. There
8     are still problems around the O edge and below 300eV, so we need to
9     understand modifications in RMF to make progress at this point.
10    
11 dlumb 1.5 VERSION 0.5 - 2000-06-23 (DL)
12     -----------
13     The initial flight calibration revealed discrepancies at the O edge
14     and the lowest energy reponses. These were attributed mainly to
15     systematic errors in the monitoring process at the Orsay synchrotron.
16     New empirical fits to the data were provided by Leicester, and these
17     have been compared with new SCISIM runs, utilising the best latest
18     electrode structure used in the Leicester analystical QE model fit. A
19     combination of LUX data, and an extension BELOW the Si L edge for the
20     SCISIM data allows a hopefully better fit. In addition I have modified
21     the QE's for the outer CCDs of each camera, where there are systematic
22     differences in QE at > 5keV. These can be attributed to ddifferences
23     in silicon resistivity translating to different depletion depths. The
24     QE data for this at Orsay is equivocal, so I take average trends in
25     increased efficiency between 5 and 12keV and allocate a best estimate
26     of increased depletion depth to this, and in return modify the overall
27     QE curves as a result. I am suspicious, though that all QE's are
28     GREATER tahn the central CCD, and this may indicate a systematic bias
29     in the measurment method at Orsay.
30    
31     The new data sets should give good results to about 10% accuracy at
32     worst case small energy scales (eg EXAFS scales at silicon edges etc.)
33    
34 dlumb 1.4 VERSION 0.4 - 2000-05-23 (DL)
35     -----------
36     FIxed error of missing pattern 1 data for CCD5
37 dlumb 1.3 VERSION 0.3 - 2000-02-23 (DL)
38     -----------
39     FIxed numerical problem in the data files (some values >>1 )
40    
41 ulammers 1.2 Version 0.2 - 2000-02-17 (UL)
42     -----------
43     + fixed minor problem with REGION expression in data files
44 ulammers 1.1
45 ulammers 1.2 Version 0.1 - 2000-02-09 (DL)
46 ulammers 1.1 -----------
47     + created by DL