1 |
gvacanti |
1.1 |
ChangeLog for emos-hkparmint |
2 |
baltieri |
1.2 |
---------------------------- |
3 |
gvacanti |
1.1 |
|
4 |
msmith |
1.5 |
Version 1.9 - 2015-01-28 (MSm) |
5 |
|
|
----------- |
6 |
|
|
In the 2014 winter eclipse season, many MOS exposures at the start of |
7 |
|
|
the science window were operating with the FP temperature several |
8 |
|
|
degrees above nominal (-120 C) due to precise thermal control not |
9 |
|
|
being possible during the G/S perigee gap. The currently allowed range |
10 |
|
|
for SAS HK GTI filtering for the FP T (E1253, K1253) of [-125.0:-115.0] |
11 |
|
|
is reduced to [-125.0:-120.0] from rev 2731 to the 1st observation of |
12 |
|
|
rev 2754 in order to allow SAS to filter out the periods of |
13 |
|
|
non-nominal FP T. Nominal observations are not affected by this |
14 |
|
|
change. |
15 |
|
|
|
16 |
ccflib |
1.4 |
Version 1.8 - 2014-02-06 (MSt) |
17 |
|
|
----------- |
18 |
|
|
Allow a second value (25 or 0) as threshold value for parameters |
19 |
|
|
E1410-1413 (EMOS1 EDU 6/7 NODE 0/1 THRES = CCD3+6) starting from |
20 |
|
|
VALDATE 2014-01-27T18:00:00 |
21 |
|
|
In rev. 2589 (2014-01-27T17:43:55) the annual tests for EMOS1 CCD3+6 |
22 |
|
|
took place, therefore EDU6+7 were switched off (=set to zero) for |
23 |
|
|
taking diagnostics of CCD3+6. After the test, a "fast EDU setup" was |
24 |
|
|
done which did not set EDU6+7 back to 25. As CCD3+6 are not used any |
25 |
|
|
more, this fast EDU setup is also used for other activities, e.g. |
26 |
|
|
FF setup. |
27 |
|
|
The pipeline crashed because hkgtigen returns empty GTI tables (as EDU |
28 |
|
|
thresholds must be 25 according to EMOS1_HK_PARMINT). |
29 |
|
|
As CCDs3+6 are not used any more due to micro-meteorite impact damages |
30 |
|
|
we surround this problem until these EDU6+7 parameters are set to 25 |
31 |
|
|
again, by also accepting value zero starting from just before |
32 |
|
|
Obs. 2589_0724940101. |
33 |
|
|
Change is only applied for EMOS1 HK_PARMINT. |
34 |
|
|
|
35 |
|
|
|
36 |
baltieri |
1.3 |
Version 1.7 - 2002-11-14 (BA) |
37 |
|
|
----------- |
38 |
|
|
Changed operating temperature limit values around -120 C: |
39 |
|
|
-125 C and -115 due to the new cooling operations starting |
40 |
|
|
in rev 533 |
41 |
|
|
|
42 |
baltieri |
1.2 |
Version 1.6 - 2002-06-05 (BA) |
43 |
|
|
----------- |
44 |
|
|
The first 4 rows, related to E1113, E1201, E1248 and E1302 |
45 |
|
|
have been removed from the HKPARMINT extension as emframes 4.11 and |
46 |
|
|
emchain 8.3 can now graciously reject CCDs in low gain mode for the |
47 |
|
|
whole exposure. |
48 |
|
|
|
49 |
|
|
Version 1.5 - 2001-9-26 (DL) |
50 |
|
|
----------- |
51 |
|
|
It was noted that the DISCARDED FRAMES counters can stay anomalously |
52 |
|
|
high after counting mode stops. Therefore we disable these checks |
53 |
|
|
it the HKGTI, and catch the counting mode durations in the emchain. |
54 |
|
|
Version 1.4 - 2001-6-15 (DL) |
55 |
|
|
----------- |
56 |
|
|
After processing several ODFs, Leicester tell us that again the limits |
57 |
|
|
are too strict. Until we know better I put them to larger range for |
58 |
|
|
temperatures |
59 |
|
|
Version 1.3 - 2001-6-8 (DL) |
60 |
|
|
----------- |
61 |
|
|
Firs t testing of the new CCF showed that there are some observations |
62 |
|
|
with the MOS temperatures ou-of-limts. In view of the fact that |
63 |
|
|
Leicester hasn't found a good correlation between gain and temperature |
64 |
|
|
this checking is only seen as a placeholder, and therefore the limits |
65 |
|
|
can be less strict |
66 |
|
|
Version 1.2 - 2001-6-4 (DL) |
67 |
|
|
----------- |
68 |
|
|
Previous version released in haste - not enough spaces in the string |
69 |
|
|
length for the OR'd expression |
70 |
|
|
Version 1.1 - 2001-6-1 (DL) |
71 |
|
|
----------- |
72 |
|
|
Changed the syntax to have EITHER NODE1 or NODE 0 usable in HIGH Gain |
73 |
|
|
mode -but not low-gain this allows SSC to process strange files |
74 |
|
|
|
75 |
|
|
Version 1.0 - 2001-5-14 (DL) |
76 |
|
|
----------- |
77 |
|
|
Responding to SOC/SAS Software Problem Report (SPR) [2037] |
78 |
|
|
Fixed 3 temperature values to ensure the min < max allowed value |
79 |
|
|
|
80 |
|
|
Version 0.3 - 2000-11-29 (DL) |
81 |
|
|
----------- |
82 |
|
|
+ FIxed the expression syntax to match the new CAL/deceit functionality |
83 |
|
|
+ changed the temperature limits and also added in the check for normal |
84 |
|
|
or low gain operation which is a problem for the SSC pipeline |
85 |
|
|
Version 0.2 - 2000-11-8 (DL) |
86 |
|
|
----------- |
87 |
|
|
Fixed a typo in the data files that made the selection expressions |
88 |
|
|
empty |
89 |
|
|
Version 0.1 - 2000-9-14 (DL) |
90 |
gvacanti |
1.1 |
----------- |
91 |
|
|
+ initial version |