1 gvacanti 1.1 ChangeLog for emos-hkparmint
2 baltieri 1.2 ----------------------------
3 gvacanti 1.1
4 msmith 1.5 Version 1.9 - 2015-01-28 (MSm)
5     -----------
6     In the 2014 winter eclipse season, many MOS exposures at the start of
7     the science window were operating with the FP temperature several
8     degrees above nominal (-120 C) due to precise thermal control not
9     being possible during the G/S perigee gap. The currently allowed range
10     for SAS HK GTI filtering for the FP T (E1253, K1253) of [-125.0:-115.0]
11     is reduced to [-125.0:-120.0] from rev 2731 to the 1st observation of
12     rev 2754 in order to allow SAS to filter out the periods of
13     non-nominal FP T. Nominal observations are not affected by this
14     change.
15    
16 ccflib 1.4 Version 1.8 - 2014-02-06 (MSt)
17     -----------
18     Allow a second value (25 or 0) as threshold value for parameters
19     E1410-1413 (EMOS1 EDU 6/7 NODE 0/1 THRES = CCD3+6) starting from
20     VALDATE 2014-01-27T18:00:00
21     In rev. 2589 (2014-01-27T17:43:55) the annual tests for EMOS1 CCD3+6
22     took place, therefore EDU6+7 were switched off (=set to zero) for
23     taking diagnostics of CCD3+6. After the test, a "fast EDU setup" was
24     done which did not set EDU6+7 back to 25. As CCD3+6 are not used any
25     more, this fast EDU setup is also used for other activities, e.g.
26     FF setup.
27     The pipeline crashed because hkgtigen returns empty GTI tables (as EDU
28     thresholds must be 25 according to EMOS1_HK_PARMINT).
29     As CCDs3+6 are not used any more due to micro-meteorite impact damages
30     we surround this problem until these EDU6+7 parameters are set to 25
31     again, by also accepting value zero starting from just before
32     Obs. 2589_0724940101.
33     Change is only applied for EMOS1 HK_PARMINT.
34    
35    
36 baltieri 1.3 Version 1.7 - 2002-11-14 (BA)
37     -----------
38     Changed operating temperature limit values around -120 C:
39     -125 C and -115 due to the new cooling operations starting
40     in rev 533
41    
42 baltieri 1.2 Version 1.6 - 2002-06-05 (BA)
43     -----------
44     The first 4 rows, related to E1113, E1201, E1248 and E1302
45     have been removed from the HKPARMINT extension as emframes 4.11 and
46     emchain 8.3 can now graciously reject CCDs in low gain mode for the
47     whole exposure.
48    
49     Version 1.5 - 2001-9-26 (DL)
50     -----------
51     It was noted that the DISCARDED FRAMES counters can stay anomalously
52     high after counting mode stops. Therefore we disable these checks
53     it the HKGTI, and catch the counting mode durations in the emchain.
54     Version 1.4 - 2001-6-15 (DL)
55     -----------
56     After processing several ODFs, Leicester tell us that again the limits
57     are too strict. Until we know better I put them to larger range for
58     temperatures
59     Version 1.3 - 2001-6-8 (DL)
60     -----------
61     Firs t testing of the new CCF showed that there are some observations
62     with the MOS temperatures ou-of-limts. In view of the fact that
63     Leicester hasn't found a good correlation between gain and temperature
64     this checking is only seen as a placeholder, and therefore the limits
65     can be less strict
66     Version 1.2 - 2001-6-4 (DL)
67     -----------
68     Previous version released in haste - not enough spaces in the string
69     length for the OR'd expression
70     Version 1.1 - 2001-6-1 (DL)
71     -----------
72     Changed the syntax to have EITHER NODE1 or NODE 0 usable in HIGH Gain
73     mode -but not low-gain this allows SSC to process strange files
74    
75     Version 1.0 - 2001-5-14 (DL)
76     -----------
77     Responding to SOC/SAS Software Problem Report (SPR) [2037]
78     Fixed 3 temperature values to ensure the min < max allowed value
79    
80     Version 0.3 - 2000-11-29 (DL)
81     -----------
82     + FIxed the expression syntax to match the new CAL/deceit functionality
83     + changed the temperature limits and also added in the check for normal
84     or low gain operation which is a problem for the SSC pipeline
85     Version 0.2 - 2000-11-8 (DL)
86     -----------
87     Fixed a typo in the data files that made the selection expressions
88     empty
89     Version 0.1 - 2000-9-14 (DL)
90 gvacanti 1.1 -----------
91     + initial version

  ViewVC Help